The MIL-PRF-16173 performance specification covers solvent-dispersed corrosion preventive compounds that deposit thin, easily removable films after evaporation of solvent.

Product Description

MIL-PRF-16173. This performance specification covers solvent-dispersed corrosion preventive compounds that deposit thin,easily removable films after evaporation of solvent.

 

Classification

Corrosion preventive compounds covered by this specification are furnished in the following classes and grades.

Classes : The classes of the corrosion preventive compounds are designated by Class I (High volatile organic compounds (VOC)) or Class II (Low VOC) as follows:

Class I – High Voc – VOC exceeding 2.8 pounds per gallon (lbs/gal) (340 grams/liter).
Class II – Low Voc – VOC not exceeding 2.8 lbs/gal (340 grams/liter).

Grades : The grades of the corrosion preventive compound are the following:

Grade 1 – Hard film (175 degrees Fahrenheit (deg F) 80 degrees Celsius (deg C) minimum flow point of solvent deposited film)
Grade 2 – Soft film
Grade 3 – Water displacing, soft film
Grade 4 – Transparent, non-tacky film
Grade 5 – Low pressure steam removable film
Please refer to the Technical Specs Tab for further Nox-Rust information, or contact us at 888-697-6001 or sales@chemsol.com, thank you.

Nox-Rust 501 LS / MIL-PRF-16173 Class I Grade 1

NOX-RUST 501-LS is a solvent type, cold application rust preventive hard film which meets the requirements of MIL-PRF-16173E, Grade I, Class I. NOX-RUST 501-LS is for the protection of metals when exposed to outdoor weather  conditions and for general purpose preservation, indoor or outdoor, with or without cover, for domestic and overseas shipment where a “dry to touch” film is required.


Nox-Rust 502 DLS / MIL-PRF-16173 Class I Grade 2

NOX-RUST 502 DLS is a petroleum based, solvent type, cold applied rust preventive formulated to fulfill the requirements of MIL-PRF-16173E Grade #2 Class I Specification. NOX-RUST 502 DLS deposits a grease like film which gives versatility in application. It is recommended for extended undercover protection of internal or external surfaces of machinery and/or materials with or without use of supplementary barrier materials. It is also applicable for outdoor protection for limited periods, where metal temperatures do not reach levels which produce prohibitive flow of the corrosion preventive film. NOX-RUST 502 DLS is completely miscible with lubricating oils which would eliminate the necessity of coating removal, in some applications.
Nox-Rust 503 DLS / MIL-PRF-16173 Class I Grade 3

NOX-RUST 503 DLS is for use where water or saline solution must be displaced from corrodible surfaces and the corrosion prevented or arrested. For protection of interior surfaces of machinery, instruments or material under cover for limited periods. For protection of critical bare steel or phosphated surfaces for extended periods when packaged with satisfactory barrier materials. Nox-Rust 503 DLS is a solvent type, cold application, rust preventive, low voc soft film that meets Specification Mil-PRF-16173E, Grade 3, Class I.

Nox-Rust 110 DLS / MIL-PRF-16173 Class I Grade 4

NOX-RUST 110 DLS is a wax-based, solvent type, cold applied, corrosion preventative designed for use on ferrous and non-ferrous metals when exposed to indoor or outdoor storage conditions. NOX-RUST 110 DLS deposits a transparent, firm, wax-like film that is readily removable by conventionally used solvents or degreasing methods. NOX-RUST 110 DLS is formulated to fulfill the requirements of MIL-C-16173E, Class I, Grade #4 Specification.

Nox-Rust 501 LS / MIL-PRF-16173 Class I Grade 1

Physical Properties and Typical Values:

Application – Dipping, spraying or brushing
Film Description – Black, slightly tacky
Thickness – mils – 2.5 (.063 mm)
Setting Time, Hours – 5 – 8
Min. Flash Point, of Compound – 105 F (41 C)
Pounds per Gallon – 7.34
Specific Gravity – 0.88
Protective Qualities: Outdoor Storage, Min. – 1 Year
Accelerated Tests: 20% Salt Spray, Min. – 14 Days
Weatherometer – 1,200 Hours

NOTE: NOX-RUST 501-LS can be removed by conventional cleaning procedures or petroleum solvents.


Nox-Rust 502 DLS / MIL-PRF-16173 Class I Grade 2

Physical Properties and Typical Values

Application – Dipping, spraying or brushing down to +40°F
Removal – Conventional cleaning procedures or petroleum solvents, alkali or emulsion cleaners
Film Type – Brown colored, greaselike film
Specific Gravity @ 72°F – 0.86
Pounds/Gallon – 7.2
Flash Point – 105°F (min.)
Film Thickness – 0.6 mils
Setting Time – 30-45 min.
Volatile Organic Compounds (lbs/gal) – 3.2 max
Protective Properties and Typical Values
Indoor Storage – 5 years (min.)
Outdoor Storage (covered) – 1 year (min.)
5% Salt Spray (ATSM-B-117) – 7 days
Humidity Cabinet (ASTM-D-1748) – 30 days

Nox-Rust 503 DLS / MIL-PRF-16173 Class I Grade 3

Physical Properties and Typical Values

Application – Dipping, spraying or brushing down to 40° F
Film – Description Brown, oily
Thickness, mils – 0.4 (0.010 mm)
Setting Time, hours – 1/2 – 3/4
Flash Point – 105°F (40°C)
Pounds per Gallon – 7.1
Specific Gravity – 0.85
Volitile Organic Compounds (lbs/gal) – 3.25
Protective Qualities and Typical Values
Outdoor Storage, Min. – Not recommended
Outdoor Storage, covered – 6 months
Accelerated Tests
100% RH @ 120°F (49°C) min. – 30 days

NOX-RUST 503 DLS can be removed by conventional cleaning procedures or petroleum solvents, alkali or emulsion cleaners. The product is completely miscible with lubricating oils which, in some cases, eliminates the need for removal of coating.

 

Nox-Rust 110 DLS / MIL-PRF-16173 Class I Grade 4

Physical Properties and Typical Values

Appearance
Product – Amber, low viscosity liquid
Film – Non-tacky, amber, wax-like, transparent film
Percent Non-Volatiles – 57% by Weight
Specific Gravity – 0.87
Pounds per Gallon – 7.3
Flash Point – 105F (Min.)
Low Temperature Flexibility, -10 deg F, 90 deg Bend – Pass-no cracking or loss of adhesion
VOC – 3.4 lbs./gal. max

Suggested Uses
– Overseas shipments of unpainted metal parts and engine housings, indoor or outdoor, with or without cover;
– Indoor protection of automotive body panels;
– Long-term, general purpose protection of metal parts, dies, tools, and rolls, where an easy-to-remove film is needed.

Protective Properties and Typical Values

Outdoor Exposure (Uncovered) – 1 Year (Min.)
Shed Exposure – 5 Years (Min.)
Salt Spray (ASTM-B-117) – 336 Hours (Min.)
Humidity Cabinets (ASTM-D-1748) – 1500 Hours (Min.)

Click On The Links Below To View Documents:

Military Performance Specification – MIL-PRF-16173
Material Safety Data Sheet (MSDS) – MIL-PRF-16173

Nox Rust 501(MIL-PRF-16173, Class I, Grade 1)

Product Information (PI) – MIL-PRF-16173, Class I, Grade 1
Material Safety Data Sheet (MSDS) – MIL-PRF-16173, Class I, Grade 1

Nox Rust 502 (MIL-PRF-16173, Class I, Grade 2)

Product Information (PI) – MIL-PRF-16173, Class I, Grade 2
Material Safety Data Sheet (MSDS) – MIL-PRF-16173, Class I, Grade 2
Material Safety Data Sheet (MSDS) – MIL-PRF-16173, Class I, Grade 2, Aerosol

Nox Rust 503 (MIL-PRF-16173, Class I, Grade 3)

Product Information (PI) – MIL-PRF-16173, Class I, Grade 3
Material Safety Data Sheet (MSDS) – MIL-PRF-16173, Class I, Grade 3

Nox Rust X-110 (MIL-PRF-16173, Class I, Grade 4)

Product Information (PI) – MIL-PRF-16173, Class I, Grade 4
Material Safety Data Sheet (MSDS) – MIL-PRF-16173, Class I, Grade 4

» Nox-Rust 501 LS / MIL-PRF-16173 Class I Grade 1
» Nox-Rust 502 DLS / MIL-PRF-16173 Class I Grade 2
» Nox-Rust 503 DLS / MIL-PRF-16173 Class I Grade 3
» Nox-Rust 110 DLS / MIL-PRF-16173 Class I Grade 4

Also Known As:

» MIL-PRF-16173
» QPL-16173
» MIL-PRF-16173A
» MIL-PRF-16173B
» MIL-PRF-16173C
» MIL-PRF-16173D
» MIL-PRF-16173E
» NoxRust
» Nox-Rust
» Nox Rust
» Nox-Rust 501
» Nox-Rust 501 LS
» Nox-Rust 502
» Nox-Rust 502 DLS
» Nox-Rust 503
» Nox-Rust 503 DLS
» Nox-Rust X-110 DLS
» Nox-Rust X-110
» MIL-C-16173

Please refer to the Brand Specs Tab for branded name/military specification equivalencies.
Below represent commercial equivalent branded product names (products which conform to the same specification:

» MIL-PRF-16173 Class I Grade 1 / Nox-Rust 501 LS
» MIL-PRF-16173 Class I Grade 2 / Nox-Rust 502 DLS / Tectyl 502C
» MIL-PRF-16173 Class I Grade 3 / Nox-Rust 503 DLS / Tectyl 894
» MIL-PRF-16173 Class I Grade 4 / Nox-Rust 110DLS / Tectyl 846

Nox-Rust 501 LS / MIL-PRF-16173 Class I Grade 1

Surface Preparation

The maximum performance of NOX-RUST 501-LS can be achieved only when the metal surfaces to be protected are clean, dry and free of rust, oil and mill scale. Daubert Chemical Company recommends that the metal substrate temperature be 50-95°F (10-35°C) at the time of product application.

Application

NOX-RUST 501-LS is formulated to be used as supplied. Ensure uniform consistency prior to use. Continued stirring is generally not required. If the product thickens due to cold storage or loss of solvent during use, contact Daubert Chemical Company. DO NOT THIN NOX-RUST 501-LS. Incorrect thinning will affect film build, dry time and product performance. Daubert Chemical Company recommends that the ambient and product temperature be 50 – 95F (10 – 35C) at time of application. NOX-RUST 501-LS can be spray or dip applied.

Removal

NOX-RUST 501-LS can be removed with a solvent borne thinner, vapor degreasing, hot alkaline wash, or low-pressure steam. NOX-RUST 501-LS can be removed from fabrics by normal dry cleaning procedures. Avoid the use of chlorinated or highly aromatic solvents when removing from painted surfaces, as these solvents may adversely affect paint.

Storage

Store NOX-RUST 501-LS at temperatures between 50-95°F (10-35°C). Mild agitation is recommended prior to use.

Caution

Adequate ventilation is required for cure and to ensure against formation of a combustible liquid. THE PARTIALLY CURED FILM SHOULD NOT BE EXPOSED TO IGNITION SOURCES SUCH AS FLARES, FLAMES, SPARKS, EXCESSIVE HEAT, OR TORCHES. Refer to Daubert’s Material Safety Data Sheet for additional handling and first aid information.

Note: The addition of any product over or under this coating is not recommended. The use of additional coatings could result in chemical incompatibility, thus adversely affecting the performance of this coating as stated in the lab data section. If a product other than Daubert Chemical Company’s recommended product is required, written authorization must be obtained from Daubert Chemical Company.

 

Nox-Rust 502 DLS / MIL-PRF-16173 Class I Grade 2

Surface Preparation

The maximum performance of NOX-RUST 502 DLS can be achieved only when the metal surfaces to be protected are clean, dry and free of rust, oil and mill scale. Daubert Chemical Company recommends that the metal substrate temperature be 50-95°F (10-35°C) at the time of product application.

Application

NOX-RUST 502 DLS is formulated to be used as supplied. Ensure uniform consistency prior to use. Continued stirring is generally not required. If the product thickens due to cold storage or loss of solvent during use, contact Daubert Chemical Company. DO NOT THIN NOX-RUST 502 DLS. Incorrect thinning will affect film build, dry time and product performance. Daubert Chemical Company recommends that the ambient and product temperature be 50 – 95F (10 – 35C) at time of application. NOX-RUST 502 DLS can be spray or dip applied.

Removal

NOX-RUST 502 DLS can be removed with TECTYL HPS solvent borne thinner, vapor degreasing, hot alkaline wash, or low-pressure steam. NOX-RUST 502 DLS can be removed from fabrics by normal dry cleaning procedures. Avoid the use of chlorinated or highly aromatic solvents when removing from painted surfaces, as these solvents may adversely affect paint.

Storage

Store NOX-RUST 502 DLS at temperatures between 50-95°F (10-35°C). Mild agitation is recommended prior to use.

Caution

Adequate ventilation is required for cure and to ensure against formation of a combustible liquid. THE PARTIALLY CURED FILM SHOULD NOT BE EXPOSED TO IGNITION SOURCES SUCH AS FLARES, FLAMES, SPARKS, EXCESSIVE HEAT, OR TORCHES. Refer to Daubert’s Material Safety Data Sheet for additional handling and first aid information.

Note: The addition of any product over or under this coating is not recommended. The use of additional coatings could result in chemical incompatibility, thus adversely affecting the performance of this coating as stated in the lab data section. If a product other than Daubert Chemical Company’s recommended product is required, written authorization must be obtained from Daubert Chemical Company.


Nox-Rust 503 DLS / MIL-PRF-16173 Class I Grade 3

Surface Preparation

The maximum performance of NOX-RUST 503 DLS can be achieved only when the metal surfaces to be protected are clean, dry and free of rust, oil and mill scale. Daubert Chemical Company recommends that the metal substrate  temperature be 50-95°F (10-35°C) at the time of product application.

Application

NOX-RUST 503 DLS is formulated to be used as supplied. Ensure uniform consistency prior to use. Continued stirring is generally not required. If the product thickens due to cold storage or loss of solvent during use, contact Daubert Chemical Company. DO NOT THIN NOX-RUST 503 DLS. Incorrect thinning will affect film build, dry time and product performance. Daubert Chemical Company recommends that the ambient and product temperature be 50 – 95F (10 – 35C) at time of application. NOX-RUST 503 DLS can be spray or dip applied.

Removal

NOX-RUST 503 DLS can be removed with a solvent borne thinner, vapor degreasing, hot alkaline wash, or low-pressure steam. NOX-RUST 503 DLS can be removed from fabrics by normal dry cleaning procedures. Avoid the use of chlorinated or highly aromatic solvents when removing from painted surfaces, as these solvents may adversely affect paint.

Storage

Store NOX-RUST 503 DLS at temperatures between 50-95°F (10-35°C). Mild agitation is recommended prior to use.

Caution

Adequate ventilation is required for cure and to ensure against formation of a combustible liquid. THE PARTIALLY CURED FILM SHOULD NOT BE EXPOSED TO IGNITION SOURCES SUCH AS FLARES, FLAMES, SPARKS, EXCESSIVE HEAT, OR TORCHES. Refer to Daubert’s Material Safety Data Sheet for additional handling and first aid information.

Note: The addition of any product over or under this coating is not recommended. The use of additional coatings could result in chemical incompatibility, thus adversely affecting the performance of this coating as stated in the lab data section. If a product other than Daubert Chemical Company’s recommended product is required, written authorization must be obtained from Daubert Chemical Company.


Nox-Rust 110 DLS / MIL-PRF-16173 Class I Grade 4

Surface Preparation

The maximum performance of NOX-RUST 110 DLS can be achieved only when the metal surfaces to be protected are clean, dry and free of rust, oil and mill scale. Daubert Chemical Company recommends that the metal substrate temperature be 50-95°F (10-35°C) at the time of product application.

Application

NOX-RUST 110 DLS can be applied by dipping, brushing or spraying. When dipped, the wet applied film thickness ranges from 3.0 to 4.0 and will dry in 1 hour to a film thickness of 1.5 to 2.0 mils. Under these conditions, NOX-RUST 110 DLS coverage is 700 sq/ft per gallon. NOX-RUST 110 DLS cures by solvents evaporation. Adequate ventilation is required for cure, and also to prevnt the formation of an explosive atmosphere. Further information is provided in the MSDS sheet.

Removal

NOX-RUST 110 DLS can be removed by using mineral spirits or kerosene-soaked towels. This product can also be removed by vapor degreasing.

Storage

Store NOX-RUST 110 DLS at temperatures between 50-95°F (10-35°C). Mild agitation is recommended prior to use.

Caution

Adequate ventilation is required for cure and to ensure against formation of a combustible liquid. THE PARTIALLY CURED FILM SHOULD NOT BE EXPOSED TO IGNITION SOURCES SUCH AS FLARES, FLAMES, SPARKS, EXCESSIVE HEAT, OR TORCHES. Refer to Daubert’s Material Safety Data Sheet for additional handling and first aid information.

Note: The addition of any product over or under this coating is not recommended. The use of additional coatings could result in chemical incompatibility, thus adversely affecting the performance of this coating as stated in the lab data section. If a product other than Daubert Chemical Company’s recommended product is required, written authorization must be obtained from Daubert Chemical Company.

Standard Packaging is as follows:

» pint
» quart
» gallon
» 5 gallon pail